For H2S the SS2100 Analyzer is capable of measuring hydrogen sulfide using tunable diode laser technology. The SS2100 delivers precise, reliable measurements and dramatically reduces maintenance costs.
This application measures H2S with typical measurements of 0-20 ppm with a repeatability of ± 500 ppb.
Application Code: 10902
Application Note
SpectraSensors SS2100 H2S Measurement Analyzer measures hydrogen sulfide in natural gas quickly and reliably without light source aging, tape replacement or ongoing recalibration.
The SS2100 H2S is perfect for remote or hazardous installations because its patented, laser based technology and requires very little annual maintenance. Factory set calibration last the full lifetime of the analyzer.
SpectraSensors analyzers are the first to offer truly dependable technology and simple operation for applications such as natural gas pipelines monitoring.
By its nature, the TDL (Tunable Diode Laser) detection method is not susceptible to aging effects. Excellent measurement repeatability between instruments compared to lab instruments makes the SS2100 H2S analyzer the ideal measurement tool for even the most punishing of environments.
Sensitive enough to meet the needs of critical tariff applications, the analyzer has operating ranges of 0-10 ppmv to percent levels and repeatability as low as ±500 ppbv.
The SS2100 H2S is remarkably easy to install; connect the power, the data link and the measured gas line and the analyzer begins working. Once set up, measurements begin within minutes.
The SS2100 H2S analyzer is available in many configurations. An optional measurement cell can be added to the analyzer for dual measurement H2S specifications, see the SS2000 product sheets.
Data Sheet
Performance |
|
|
Target Components |
H2S in Natural Gas |
|
Typical Measurement Ranges |
0-20 ppm* |
|
Typical Precision |
±500ppb |
|
Measurement Response Time |
16 seconds**
|
|
Principle of Measurement |
Tunable Diode Laser Absorption Spectroscopy
|
|
Environmental Temperature Range |
-20º to 50ºC (-4º to 122ºF)
-15º to 60º C (-5º to 140º F) optional
|
|
Sample Inlet Pressure |
130 - 340 kPaG
(20-50 PSIG) to panel |
|
Sample Cell Temperature Range |
-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (-5º to 140ºF)
|
|
Maximum Cell Pressure |
70 kPag (10 PSIg) |
| Sample Flow Rate |
3 L/min (5.4 scfh) |
| Recommended Validation | Binary Cal Gas Bottle with Methane Background |
Electrical |
|
|
Voltage |
100-240 VAC, 50-60 Hz |
|
Max Current |
2 amp maximum @ 120 VAC
1 amp maximum @ 120 VAC
|
|
Communication |
Generic or Modbus RS232C
4-20mA loop
|
| Digital Outputs |
2, General Fault and Concentration Alarm |
| LCD Display |
Concentration, Cell Pressure and Temperature
& Diagnostics
|
Physical |
|
|
Controller Enclosure |
NEMA 4X - stainless steel standard |
|
Dimensions |
610mm H x 1372mm W x 330mm H
(24" H x 54" W x 13" D) |
|
Weight Approximately |
Approx 91Kg (200lbs) |
|
Sample Cell Dimensions |
438mm H x 108mm W
(17-1/4” H × 4-1/4” W) |
|
Sample Cell Construction |
316L Series Polished Stainless Steel standard |
| Number of Sample Cells |
1 (2-cell or 3-cell systems available)
|
| Area Classification |
CSA Certified for Class I, Division 2,
Groups ABCD, Temp Code T3C
|
| * Typical Shown; custom configurations available |
|
|
** Application specific; consult factory
|
|