Skip to Content

4333 W. Sam Houston Pkwy N., Suite 100 Houston, TX 77043 | D: +1 713 300-2700 | TF: 800 619-2861 | F: +1 713 856-6623

2-Pack - H2S+H2O Analyzer System

 
The SpectraSensors H2S + H2O 2-Pack gas analyzer systems retains the analytical benefits and reliability known by our existing customers. In addition, reduced installation costs, support and complexity  are achieved via a single technology for gas quality measurements.
 Product Code: 11006

 


Application Note

Gas Quality Simplified
The analyzer system includes all required sample conditioning and regulation. The sample system is heated to 50°C (122°F) to keep all constituents in vapor phase.

Training requirements are reduced and the system enables fewer electrical runs, fewer sample runs and less labor. Installation and operational costs are dramatically reduced.


 
The Installation diagram on the left is a simple representation of connection to the pipeline.
 
A variety of sample probe products are available to compliment the application.
 
SpectraSensors offers probes, probe regulators, and heated regulators depending on the pressure in the pipeline, the gas and ambient temperatures and the hydrocarbon dew point.
 

« Previous | Next »

Data Sheet

 

Performance

Target Components

H2S + H2O in Natural Gas

Typical Measurement Ranges - H2S

0-20 ± 0.5ppmv (other ranges available)
Typical Measurement Ranges - H2O 0-20 ± 2lb/MMscf (other ranges available)

Measurement Update Time

H2S: 2 seconds
H2O: 1 second
Total system response is dependant on
flow rate and sample system volume

Principle of Measurement

Tunable Diode Laser Absorption Spectroscopy

Environmental Temperature Range

-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional

Sample Inlet Pressure

1.5-4 barG (20-50 PSIG) to enclosure inlet

Cell Temperature

-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional

Maximum Cell Pressure

70 kPag (10 PSIG)

Sample Flow Rate
H2S: 2-4L/min (4 to 8 scfh)
H2O: 0.1-2L/min (0.2 to 4 scfh)
Recommended Validation
H2O: Bureau of Mines Chilled Mirror
H2S: Binary Cal Gas Bottle with Methane Background
 

Electrical

Voltage

100-240 VAC, 50-60 Hz standard

Max Current

3A max @ 120 VAC
1.5A nax @ 24VAC Hz

Communication

4-20mA loop (concentration only), RS232 (all parameters)
Digital Outputs
2, 1 General Fault and 1 Hi/Lo Concentration Alarm
per measurement cell
LCD Display
Concentration, Cell Pressure and Temperature & Diagnostics
 

Physical

Controller Enclosure

NEMA 4X - standard

Dimensions

1450 mm H × 760 mm W × 330 mm D
(57” H × 30” W × 13” D)

Weight

Approximately 154Kg (340lbs)

Sample Cell Dimensions

438mm H x 108mm W
(17-1/4” H × 4-1/4” W)

Sample Cell Construction

316L Series Polished Stainless Steel standard

Number of Sample Cells
2
Area Classification
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C



 

Drawings

 
 
 

« Previous | Next »

Typical Accessories




 
 
 

Photos

 

« Previous | Next »

Request a Quote

To request a quote online, please enter the following and we'll get back to you promptly:

Your Name*
Company
Email*
Address*
Address Line 2
City*
State
Zip Code
Country*
Phone
Product Code
Application Name / Stream Details
Measurement Range
Comments and Questions

« Previous | Next »