The SpectraSensors H2S + CO2 2-Pack gas analyzer systems retains the analytical benefits and reliability known by our existing customers. In addition, reduced installation costs, support and complexity are achieved via a single technology for gas quality measurements.
Product Code: 11107
Application Note
Gas Quality Simplified
The analyzer system includes all required sample conditioning and regulation. The sample system is heated to 50°C (122°F) to keep all constituents in vapor phase.
Training requirements are reduced and the system enables fewer electrical runs, fewer sample runs and less labor. Installation and operational costs are dramatically reduced.
The Installation diagram on the left is a simple representation of connection to the pipeline.
A variety of sample probe products are available to compliment the application.
SpectraSensors offers probes, probe regulators, and heated regulators depending on the pressure in the pipeline, the gas and ambient temperatures and the hydrocarbon dew point.
« Previous | Next »
Data Sheet
Performance
|
|
Target Components
|
H2S + CO2 in Natural Gas
|
|
Typical Measurement Ranges - H2S
|
0-20 ± 0.5ppmv (other ranges available)
|
| Typical Measurement Ranges - CO2 |
0-10 ± 0.04% (other ranges available) |
|
Measurement Update Time
|
H2S: 2 seconds
CO2: 1 second
Total system response is dependant on
flow rate and sample system volume
|
|
Principle of Measurement
|
Tunable Diode Laser Absorption Spectroscopy
|
|
Environmental Temperature Range
|
-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional
|
|
Sample Inlet Pressure
|
1.5-4 barG (20-50 PSIG) to enclosure inlet
|
|
Cell Temperature
|
-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional
|
|
Maximum Cell Pressure
|
70 kPag (10 PSIG)
|
Sample Flow Rate
|
H2S: 2-4L/min (4 to 8 scfh)
CO2: 0.1-2L/min (0.2 to 4 scfh)
|
| Recommended Validation |
H2O: Bureau of Mines Chilled Mirror
CO2: Binary Cal Gas Bottle with Methane Background
|
| |
Electrical
|
|
Voltage
|
100-240 VAC, 50-60 Hz standard
|
|
Max Current
|
3A max @ 120 VAC
1.5A nax @ 24VAC Hz
|
|
Communication
|
4-20mA loop (concentration only), RS232 (all parameters)
|
Digital Outputs
|
2, 1 General Fault and 1 Hi/Lo Concentration Alarm
per measurement cell
|
LCD Display
|
Concentration, Cell Pressure and Temperature & Diagnostics
|
| |
Physical
|
|
Controller Enclosure
|
NEMA 4X - standard
|
|
Dimensions
|
1450 mm H × 760 mm W × 330 mm D
(57” H × 30” W × 13” D) |
|
Weight
|
Approximately 154Kg (340lbs) |
|
Sample Cell Dimensions
|
438mm H x 108mm W
(17-1/4” H × 4-1/4” W)
|
|
Sample Cell Construction
|
316L Series Polished Stainless Steel standard
|
Number of Sample Cells
|
2
|
Area Classification
|
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C
|
|
|
|