Control H2S in Refinery Propane/Propylene Mix using Tunable Diode Laser technology.
Product Code: 23502
 
 
 
 
 

Application Note

Propane/Propylene Mix
There are three major sources of pure Propylene for polypropylene feed: Refinery Fluidized Catalytic Cracking (FCC) byproduct, Ethylene Cracking Furnaces as a byproduct of Ethylene production and Propane dehydration; of these three, Refinery FCC byproduct is by far the largest source.

Sulfur compounds in the feed to the FCC unit are converted to H2S and follow the Propane/Propylene product.

Depending on the processing, there are three different products: an essential pure Propane, a 65/35 mix of Propane/Propylene and a 35/65 Propane/Propylene mix (see stream composition table). These products are further refined for their eventual use.

Critical Control of H2S
The primary method of H2S control is removal in the stripper section of the vapor recovery unit.

Traditional Measurement Solutions
Lead Acetate paper tape analyzers have been used but they require frequent replacement of the paper tape and many regard the paper tape itself as a handling and disposal problem due to its lead content. Gas Chromatographs have often been used but the desired measurements require Flame Photometric and other trace sulfur detectors that can be maintenance intensive.

SpectraSensors’ Solution
The SpectraSensors SS2100 offers a new solution to this challenging measurement. There are no cylinder gases or Lead Acetate tapes to replace on a routine basis, so the analyzer is very low maintenance and has a low cost of ownership over the life of the analyzer. The high resolution that is inherent to TDL technology eliminates errors due to interferences that have hampered other spectrometric approaches.

Only SpectraSensors employs Differential Spectroscopy to cope with the changes in background spectrum of the sample caused by changing operating conditions and feedstocks. The sample gas is passed through a copper nanoparticle scrubber to remove H2S, and the spectrum of the H2S-free sample is measured. The scrubber is then bypassed to measure the raw sample with H2S, and the H2S is measured by spectral subtraction. As the H2S-free background spectrum can be applied repeatedly to the sample, the scrubber is only used as needed, controlled by logic in the electronic controller.

The scrubber lifetime in normal service is a minimum of 18 months, so consumable costs and maintenance are low. Tunable Diode Laser technology means that analysis is fast; results can be updated every second if desired.

Typical Stream Composition

Stream Composition

 

Background 1 - Propane

 

Component

 

Minimum (Mole %)

 

Normal (Mole %)

 

Maximum (Mole %)

 

Ethane

 

0

 

1

 

2

 

Propane

 

65

 

78

 

100

 

Propylene

 

0

 

20

 

35

 

C4+

 

0

 

1

 

2.5

 

 

Stream Composition

 

Background 2 - 35/65

 

Component

 

Minimum (Mole %)

 

Normal (Mole %)

 

Maximum (Mole %)

 

Ethane

 

0

 

1

 

2

 

Propane

 

0

 

20

 

35

 

Propylene

 

65

 

78

 

100

 

C4+

 

0

 

1

 

2

 

 

Stream Composition

 

Background 3 - 65/35

 

Component

 

Minimum (Mole %)

 

Normal (Mole %)

 

Maximum (Mole %)

 

Ethane

 

0

1

 

2

 

Propane

 

65

 

78

 

100

 

Propylene

 

0

 

20

 

35

 

C4+

 

0

 

1

 

2.5

 

 



The background stream composition must be specified for proper calibration and measurement performance.  Specify the Normal composition, along with the minimum and maximum expected values for each component, especially H2S, the measured component.  Other stream compositions may be allowable with approval from SpectraSensors.

 

« Previous | Next »

Data Sheet


Performance

Target Components

H2S in Propane/Propylene (C3) Product

Typical Measurement Ranges

0 – 10 ppm*

Typical Precision

±0.5 ppm

Measurement Response Time

1 to ~60 sec

Principle of Measurement

Differential Tunable Diode Laser Absorption Spectroscopy
(H2S Scrubber Included)

Environmental Temperature Range

-20º to 50ºC (-4º to 122ºF)
-10º to 60ºC (14º to 140ºF) optional

Sample Inlet Pressure

70 kPag (10 psig) typical

210 kPag (30 psig) maximum

Cell Temperature

Maintain at 50ºC +/- 0.2ºC

Maximum Cell Pressure

70 kPag (10 PSIg)

Sample Flow Rate
 
3-4 L/min (6.4 to 8.5 scfh)*
Validation
A certified blend of H2S in N2 is
diluted with dried sample in the sample
conditioning system under flow control
 

Electrical

Power

100-240 VAC, 50-60 Hz standard

Max Current

Controller: 1 A @ 120 VAC

Controller to Cell Cable Length

1m standard (3m, 5m & 10m available optionally)

Communication

Current Loop Output 4-20 mA Isolated,
1200 ohms @ 24 VDC max load
Serial: ASCII Text RS232C standard
Modbus RS232C
Digital Outputs
4 ea. 12 VDC for valve operations
Scrubber (if required), Process/Val, Val 1, Val 2
5 SPDT (Form C) Dry Contact Alarms
Common Fault, Val 1 Active, Val 2 Active, Val Fail,
one user-assignable to any alarm 
LCD Display
Concentration, Cell Pressure and Temperature, Diagnostic Data
 

Physical

Controller Enclosure

NEMA 4X - Stainless Steel standard

Controller Dimensions

343mm H x 305mm W x 165mm H
(13.5" H x 12" W x 6-7/16" D)*

Weight Approximately

13.1 Kg (28.6 lbs)*

Sample Cell Dimensions

28m Herriot Cell
559 mm H × 127 mm W
(22” H × 5” W)

Sample Cell Construction

316L Series Polished Stainless Steel standard 
SilcoNert® coated
Number of Sample Cells
1 (single channel SS2100) or
2 (dual channel SS2100)
Area Classification
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C
 ll 2G Ex d llB+H2 T5; Tamb : -20 ÷ +60 °C
Dimensions with Sample System 1678 mm H x 613 mm W x 427 mm D
(66” H x 24-1/8” W x 16-13/16” D)
Weight with Sample System (approx.) 68 kg (150 lbs.)

* Application specific; consult factory

« Previous | Next »

Drawings


Typical Accessories


SS2100 ARM9 Electronics
 

80000-02199

Temperature Control Board

23000-00030

4-20 mA Current Loop Board
 

80000-02203

Power Supply Assembly, 120/240 VAC 50/60 Hz
 

80000-02300

Power Supply Assembly, 24 VDC
 

01902-17106 External Serial Output Cable

01902-30011 Keypad Assembly

24601-00002
Display Assembly
 
02203-13100
Daughter Board
 
45000-02002
Relay, DC12V SPDT 3 A/120 VAC
 

Herriott Cell (8m & 28m)
02101-17102
Pressure Transducer Assembly
 
02101-17103
Thermistor Assembly
 
02199-00006
Spares Kit (o-rings, fuses), AC, Viton
 
02199-00007
Cleaning Kit (domestic only)
 
 

Photos

 
 

« Previous | Next »

Request a quote

To request a quote online, please enter the following and we'll get back to you promptly:

Your Name*
Company
Email*
Address*
Address Line 2
City*
State
Zip Code
Country*
Phone
Product Code
Application Name / Stream Details
Measurement Range
Comments and Questions

« Previous | Next »