Overview
Specific
The HCD4000™ will display the dewpoint temperature and indicate whether it is hydrocarbon or not.
Reliable
The CEIRS™ method utilizes a highly inert ceramic sensor element and is immune to contamination. The IR light does not travel through any gas so there are no false signals due to particulate scattering. Therefore the analyzer is very robust and requires little maintenance.
Fast and EasyThe HCD4000 is designed for remote operation at line pressure up to 1500psi. The dewpoint
temperature is updated every 15 minutes and the gas runs continuously.
This chart shows the correlation between the measured and theoretical dew points in a gas sample. The instrument performs with very low uncertainty.
Data Sheet
Performance |
|
| Dewpoint Measurement Range | 90°F (50°C) below ambient |
| Lowest | -13°F (-25°C) |
| Dewpoint Accuracy | <±0.9 °F (<±0.5 °C) |
| Measurement Time | 12-20 minutes typical |
Application Conditions |
|
| Operating Temperature | 14 to +104 °F (-10 to +40 °C) |
| Storage Temperature | -4 to +122 °F (-20 to +50 °C) |
| Flow Rate | 0.005-0.1 SCFM (0.1-3 SLPM) |
| Pressure | 0-1500 PSIG (0-103 bar) |
| Altitude | Up to 2000 m |
Electrical & Communications |
|
| Input Voltage | 100-240VAC (47-63Hz); or 18-30VDC optional |
| Power Usage | 100 W Max, <50 W average (depends on ambient temperate) |
| Signal Outputs | Qty 4 4-20mA loop, Qty 2 RS232, 3 DO Relays (General Fault + 2 Hi/Lo) |
| Protocol | Modbus Gould RTU, Daniel RTU - optional |
| Display | Dewpoint, Cell Temperature and Pressure, Modes & Errors |
| PC Software | SpectraSensors AMS100™ Enables system config, autopoll, history, data export, etc. |
Certification |
|
| Hazardous Location | Field Certified CSA Class I, Division 1, Groups C&D, T6 |
Physical |
|
| Size | 420mm (17 in) X 575mm (22.25 in) X 300mm (12 in) |
| Weight | 45kg (100 lb) Analyzer only 59kg (130 lb) Analyzer and Sample System |
Sample Conditioning
PONY
|
|||||||||||||||||||
Heated Probe Enclosure |
|||||||||||||||||||
|
The Pony® Heated Probe Enclosure is designed to provide and maintain heat for the sample probe directly at the sample point with a P53 Heated Sample Conditioning System. The Pony® enclosure is an integral part of the P53, developed to install between 6” center-to-center thread-o-lets. |
Consisting of a molded, insulated, and weatherproof clam shell design, the Pony® enclosure provides easy maintenance with steel latches and chain to prevent loss of lid. Construction selections include hot press glass fiber reinforced polyester or stainless steel. |
||||||||||||||||||
|
|
|||||||||||||||||||
PONY |
|||||||||||||||||||
Heated Probe Enclosure |
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|||||||||||||||||||