HCD4000 - Hydrocarbon Dewpoint Analyzer

HCD4000 - Hydrocarbon Dewpoint AnalyzerSpectraSensors HCD4000™ Hydrocarbon Dewpoint Analyzer has an accuracy of ±0.5 °C and it can discriminate hydrocarbon dewpoint from moisture or glycol. The analyzer uses “Chilled Evanescent IR Spectroscopy” or CEIRS™. The patented technique is very simple and robust and can optically discriminate hydrocarbon liquids from other liquids. 
 
 
 
 
 

Overview

 

Specific

The HCD4000™ will display the dewpoint temperature and indicate whether it is hydrocarbon or not.


Reliable

The CEIRS™ method utilizes a highly inert ceramic sensor element and is immune to contamination. The IR light does not travel through any gas so there are no false signals due to particulate scattering. Therefore the analyzer is very robust and requires little maintenance.

Fast and Easy

The HCD4000 is designed for remote operation at line pressure up to 1500psi. The dewpoint
temperature is updated every 15 minutes and the gas runs continuously.

 
Precise and Repeatable

This chart shows the correlation between the measured and theoretical dew points in a gas sample. The instrument performs with very low uncertainty.

 

 

« Previous | Next »

 

Data Sheet


Performance

Dewpoint Measurement Range 90°F (50°C) below ambient
Lowest -13°F (-25°C)
Dewpoint Accuracy <±0.9 °F (<±0.5 °C)
Measurement Time 12-20 minutes typical
   

Application Conditions

Operating Temperature 14 to +104 °F (-10 to +40 °C)
Storage Temperature -4 to +122 °F (-20 to +50 °C)
Flow Rate 0.005-0.1 SCFM (0.1-3 SLPM)
Pressure 0-1500 PSIG (0-103 bar)
Altitude Up to 2000 m
   

Electrical & Communications

Input Voltage 100-240VAC (47-63Hz); or 18-30VDC optional
Power Usage 100 W Max, <50 W average (depends on ambient temperate)
Signal Outputs Qty 4 4-20mA loop, Qty 2 RS232, 3 DO Relays (General Fault + 2 Hi/Lo)
Protocol Modbus Gould RTU, Daniel RTU - optional
Display Dewpoint, Cell Temperature and Pressure, Modes & Errors
PC Software SpectraSensors AMS100™ Enables system config, autopoll, history, data export, etc.
   

Certification

Hazardous Location Field Certified CSA Class I, Division 1, Groups C&D, T6
   

Physical

Size 420mm (17 in) X 575mm (22.25 in) X 300mm (12 in)
Weight 45kg (100 lb) Analyzer only
59kg (130 lb) Analyzer and Sample System

 

« Previous | Next »

Drawings

 
 

Typical Accessories

More information coming soon. 

Sample Conditioning

PONY   PONY Heated Probe Enclosure

Heated Probe Enclosure

The Pony® Heated Probe Enclosure is designed to provide and maintain heat for the sample probe directly at the sample point with a P53 Heated Sample Conditioning System.

The Pony® enclosure is an integral part of the P53, developed to install between 6” center-to-center thread-o-lets.

Consisting of a molded, insulated, and weatherproof clam shell design, the Pony® enclosure provides easy maintenance with steel latches and chain to prevent loss of lid.

Construction selections include hot press glass fiber reinforced polyester or stainless steel.

 

PONY

Heated Probe Enclosure

Product Specifications

Power 12 VAC/240 VAC/24 VDC
Heating Components 50 watt self-limiting block heater
Sample Gas Temperature Maintained 90ºF (37ºC)
Cabinet Construction Hot-pressed Glass Fiber Reinforced Polyester

Standard Components

  • Heated insulated enclosure
  • Class 1, Div 1 Termination enclosure w/ termination kit
  • Heat tracing tubing shrink boot
  • Bolts, nuts, & washers to mount to adapter nut
  • Heat trace tubing shrink sleeve
  •  
     