SS3000e - Enhanced Dual H2O / CO2 Analyzer Solution
Application Note
SpectraSensors SS3000e Dual Channel Gas Analyzer is capable of measuring moisture and carbon dioxide in this cost effective dual channel system which enhances cost savings by incorporating two sensors in one.
The TDL sensor never comes into contact with the sample gas stream. The result is a sensor which does not suffer from contamination or drift due to vapor impurities such as glycol, methanol or amines.
The SS3000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.
Data Sheet
Performance |
|
|
Target Components |
H2O/CO2 in Natural Gas |
|
Typical Measurement Ranges - H2O |
0-422ppmv (0-20 lb/MMscf) Ranges up to 10,000ppmv available* |
|
Typical Precision - H2O |
±4ppmv |
| Typical Measurement Ranges - CO2 | 0-5% and 0-10% |
| Typical Precision - CO2 | ±1% of reading or ±0.04ppmv (400ppmv), whichever is greater |
|
Measurement Response Time |
0.25-2 seconds (Total system response dependent on flow rate and sample system volume) |
|
Principle of Measurement |
Tunable Diode Laser Absorption Spectroscopy
|
|
Environmental/Sample Temperature Range |
-20º to 50º C (-4º to 122º F)
-10º to 60º C (14º to 140º F) optional
|
|
Sample Pressure |
Maximum cell pressure 70kPaG (10 psig) |
| Sample Flow Rate |
0.5-1 L/min (1-2 scfh) |
| Validation |
H2O -Bureau of Mines Chilled Mirror or Portable TDL
CO2 - Binary Cal Gas Bottle with Methane Background
|
Electrical |
|
|
Input Voltage |
100-240 VAC, 50-60 HZ |
|
Max Current (unheated) |
1 amp maximum @ 120 VAC , 1.6A @ 24VDC |
|
Max Current (heated) |
2 amps maximum @ 120 VAC |
| Communication |
Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load Serial: RS232C standard, RS485 and Ethernet Optional Protocol: Modbus Gould RTU or Daniel RTU or ASCII |
| Digital Outputs |
2, General Fault and Concentration/Assignable Alarm |
| LCD Display |
Concentration, Cell Pressure, Temperature, Alarms & Diagnostics |
Physical |
|
|
Enclosure Type |
NEMA 4X Stainless Steel Enclosures |
|
Dimensions |
973, 406, 224mm (38.3, 16, 8.8 inches) |
|
Approximate Weight |
45kg (100lbs) |
|
Sample Cell Dimensions |
438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)
|
|
Sample Cell Construction |
316L Series Polished Stainless Steel standard |
| Number of Sample Cells |
2
|
| Area Classification |
CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters) |
Typical Accessories
|
Part Number |
Description |
|
01902-17106 |
External Serial Output Cable1 |
|
01902-13000 |
Temperature Control Board |
|
01902-14000 |
4-20 mA Current Loop Board |
|
80000-02480 |
Power Supply & Filter 120/240 VAC 50/60 Hz |
|
80000-02481 |
Power Supply & Filter 12 VDC |
|
80000-02482 |
Power Supply & Filter 24 VDC |
|
31000-02151 |
Filter, Power Line 120/240 VAC, 5 amps |
|
80000-02484 |
Ethernet Converter 2-Channel |
|
80000-02486 |
RS-485 Converter 2-Channel |
|
01902-30011 |
Keypad Assembly |
|
24000-02087 |
Display Assembly |
|
45000-02002 |
Relay, DC12V SPDT 3 A/120 VAC |
|
80000-02474 |
Pressure Transducer Assembly |
|
24000-02088 |
Cable Gland/Seal, 9-Position, Roxtec RG00063090046 |
|
02199-00005 |
Kit, O-rings Viton, 2-Pass Cell1 |
|
02199-00011 |
Kit, Fuse, AC, DC1 |
|
02199-00007 |
Kit, Cleaning Tools, Optical Cell |
|
01910-30017 |
Stainless Steel Tag (up to 2 lines of text) |
|
00000-02015 |
Extended Calibration 100lbs moisture |
|
49000-02068 |
Instruction Manuals (up to 2 copies at no charge), additional copies |
|
61303-042S4 |
Ball Valve, 1/4” TF SS Swagelok SS-42GS4 |
|
61015-20074 |
Filter, Tee-Type, 7µm, 1/4” TF SS Swagelok SS-4TF-7 |
|
61000-02186 |
Filter Element, 7µm Swagelok SS-4F-K4-71 |
|
61016-71208 |
Membrane Separator, 1/4" NPTF SS A+ Corp 120-005-SS |
|
61016-120X5 |
Membrane Replacement Filter A+ Corp 120-5X51 |
|
61341-00274 |
Flow Meter w/Valve 2 SLPM, 1/4" NPTF SS King 74C123G081123810 |
|
28000-02041 |
Rebuild Kit, Flowmeter, Viton, King 74301 |
|
61321-25254 |
Pressure Regulator, 25psig, 1/4” NPTF SS GO PR1-1A11A3D111 |
|
61000-02004 |
Pressure Gauge, 0–30 psig McDaniel SBL / Parker 9118128 |
|
62000-00006 |
Pressure Gauge, 0–60 psig McDaniel SCL / Parker 9118101 |
|
55032-340B6 |
Temperature Gage, 3”, 200F, 4” Stem, 1/2" NPT Reotemp AA-040-1-043 |
|
28011-19112 |
Watertight Conduit Hub 3/4 inch, Appleton HUB-75D |
|
53000-02017 |
Heater 100W, 120 VAC Intertec CP Multitherm CNA 100 T3 120V |
|
53000-02018 |
Heater 100W, 230 VAC Intertec CP Multitherm CNA 100 T3 230V |
Sample Conditioning
P53
|
|||||||||||||||||||||
HEATED SAMPLE CONDITIONING |
|||||||||||||||||||||
|
The P53 Heated Sample Conditioning System ensures performance of gas analyzer by delivering a heated sample through patented technology to the analyzer. This avoids costly errors resulting from hydrocarbon dew point drop out by the maintaining at least 30ºF above the expected hydrocarbon dew point. |
The gas sample is heated inside of the regulator before and after the pressure is reduced eliminating hydrocarbon liquid condensation caused by the Joule Thomson effect during the pressure reduction. |
||||||||||||||||||||
|
|
|||||||||||||||||||||
P53 |
|||||||||||||||||||||
HEATED SAMPLE CONDITIONING SYSTEM |
|||||||||||||||||||||
|
|
|||||||||||||||||||||
|
|||||||||||||||||||||
PONY |
|||||||||||||||||||
HEATED PROBE ENCLOSURE |
|||||||||||||||||||
|
The Pony® Heated Probe Enclosure is designed to provide and maintain heat for the sample probe directly at the sample point with a P53 Heated Sample Conditioning System. The Pony® enclosure is an integral part of the P53, developed to install between 6” center-to-center thread-o-lets. |
Consisting of a molded, insulated, and weatherproof clam shell design, the Pony® enclosure provides easy maintenance with steel latches and chain to prevent loss of lid. Construction selections include hot press glass fiber reinforced polyester or stainless steel. |
||||||||||||||||||
|
|
|||||||||||||||||||
PONY
|
|||||||||||||||||||
HEATED PROBE ENCLOSURE |
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|||||||||||||||||||